SiBE041029EC Functions
List of Functions 2
1. Functions
Category Functions
FTX50/60/71GV1B
RX50/60G2V1B, RX50/60G2V1B9
RX50/60G3V1B, RX60G4V1B
RX71GV1B, RX71GV1B9, RX71GV1B8
Category Functions
FTX50/60/71GV1B
RX50/60G2V1B, RX50/60G2V1B9
RX50/60G3V1B, RX60G4V1B
RX71GV1B, RX71GV1B9, RX71GV1B8
Basic Function Inverter (with inverter power control)
z
Health & Clean Air-purifying filter
Operation limit for cooling (°CDB)
–10
~46
Photocatalytic deodorizing filter
Operation limit for heating (°CWB)
–15
~18
Air-purifying filter with photocatalytic
deodorizing function
PAM control
z
Titanium apatite photocatalytic
air-purifying filter
z
Standby electricity saving
Compressor Oval scroll compressor Air filter (prefilter)
z
Swing compressor
z
Wipe-clean flat panel
z
Rotary compressor Washable grille
Reluctance DC motor
z
MOLD PROOF operation
Comfortable
Airflow
Power-airflow flap Heating dry operation
Power-airflow dual flaps
z
Good-sleep cooling operation
Power-airflow diffuser Timer WEEKLY TIMER operation
Wide-angle louvers
z
24-hour ON/OFF TIMER
z
Auto-swing (up and down)
z
NIGHT SET mode
z
Auto-swing (right and left)
z
Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
z
3-D airflow
z
Self-diagnosis (R/C, LED)
z
COMFORT AIRFLOW operation Wiring error check function
Comfort
Control
Auto fan speed
z
Anti-corrosion treatment of outdoor
heat exchanger
z
Indoor unit quiet operation
z
NIGHT QUIET mode (automatic) Flexibility
Multi-split / split type compatible indoor unit
OUTDOOR UNIT QUIET operation
(manual)
z
Flexible power supply correspondence
INTELLIGENT EYE operation
z
High ceiling application
Quick warming function
(preheating control)
z
Chargeless 10 m
Either side drain (right or left)
z
Hot-start function
z
Power selection
Automatic defrosting
z
Remote
Control
5-room centralized controller (option)
z
Operation Automatic operation
z
Remote control adaptor
(normal open pulse contact) (option)
z
Program dry operation
z
Fan only
z
Remote control adaptor
(normal open contact) (option)
z
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
DIII-NET compatible (adaptor) (option)
z
Inverter POWERFUL operation
z
Remote
Controller
Wireless
z
Priority-room setting Wired (option)
z
COOL / HEAT mode lock
HOME LEAVE operation
z
ECONO operation
Indoor unit ON/OFF button
z
Signal receiving sign
z
R/C with back light
Temperature display
Note:
z
: Available
— : Not available
: Lower limit can be extended by turning switch or
cutting jumper. (facility use only)
Refer to page 109 for detail.