SiBE041029EC Main Functions
Function and Control 26
1.8 NIGHT SET Mode
Outline When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Detail NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in cooling, or lowers it slightly in heating.
This prevents excessive cooling in summer and excessive heating in winter to ensure
comfortable sleeping conditions, and also conserves electricity.
<Cooling>
<Heating>
1.9 HOME LEAVE Operation
Outline HOME LEAVE operation is a function that allows you to record your preferred set temperature
and airflow rate. You can start your preferred operation mode simply by pressing the HOME
LEAVE button on the remote controller.
Detail The indoor unit is operated according to the set temperature and airflow rate for HOME LEAVE
which were recorded in the memory of the remote controller.
Start of Function
The function starts when the HOME LEAVE button is pressed in cooling operation, heating
operation (including POWERFUL operation), or while the operation is stopped.
A mark representing HOME LEAVE is indicated on the display of the remote controller, and the
LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when the operation is
stopped.)
If the HOME LEAVE button is pressed in POWERFUL operation, the POWERFUL operation
is canceled and the HOME LEAVE function becomes effective.
The HOME LEAVE button is ineffective in dry operation and fan operation.
(R22018)
TIMER operation
NIGHT SET Mode ON
Target temperature
+0.5˚C
temperature shift
Operation stops
at the set hours
0.5˚C
1 hour
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C temperature
shift
1 hour
2˚C