Loading...
Specifications SiBE041029EC
5 Specifications
50 Hz, 220 - 230 - 240 V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Unit FTX71GV1B
Outdoor Unit
RX71GV1B
Cooling Heating
Capacity Rated
(Min. ~ Max.)
kW 7.1 (2.3 ~ 8.5) 8.2 (2.3 ~ 10.2)
Btu/h 24,200 (7,800 ~ 29,000) 28,000 (7,800 ~ 34,800)
kcal/h 6,110 (1,980 ~ 7,310) 7,050 (1,980 ~ 8,770)
Running Current Rated A 10.8 - 10.4 - 9.9 11.7 - 11.2 - 10.7
Power Consumption Rated
(Min. ~ Max.)
W 2,350 (570 ~ 3,200) 2,550 (520 ~ 3,820)
Power Factor % 98.9 - 98.2 - 98.9 99.1 - 99.0 - 99.3
COP Rated
(Min. ~ Max.)
W/W 3.02 (4.04 ~ 2.66) 3.22 (4.42 ~ 2.67)
Piping
Connections
Liquid mm φ 6.4
Gas mm φ 15.9
Drain mm φ 18.0
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30
Max. Interunit Height Difference m 20
Chargeless m 10
Amount of Additional Charge of
Refrigerant
g/m 20
Indoor Unit FTX71GV1B
Front Panel Color White
Airflow Rate
H
m³/min
(cfm)
17.4 (614) 19.7 (696)
M 14.6 (516) 16.9 (597)
L 11.6 (410) 14.3 (505)
SL 10.6 (374) 12.7 (448)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.21 - 0.20 - 0.19 0.28 - 0.27 - 0.26
Power Consumption (Rated) W 45 - 45 - 45 60 - 60 - 60
Power Factor % 97.4 - 97.8 - 98.7 97.4 - 96.6 - 96.2
Temperature Control Microcomputer Control
Dimensions (H × W × D) mm 290 × 1,050 × 238
Packaged Dimensions (H × W × D) mm 337 × 1,147 × 366
Weight (Mass) kg 12
Gross Weight (Gross Mass) kg 17
Sound
Pressure
Level
H / M / L / SL dB(A) 46 / 42 / 37 / 34 46 / 42 / 37 / 34
Sound Power Level dB 62 62
Outdoor Unit RX71GV1B
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC63BXD
Motor Output W 1,920
Refrigerant
Oil
Type FVC50K
Charge L 0.75
Refrigerant
Type R-410A
Charge kg 2.30
Airflow Rate
HH
m³/min
(cfm)
57.1 (2,016)
H 54.5 (1,924) 46.0 (1,624)
SL 46.0 (1,624) 46.0 (1,624)
Fan
Type Propeller
Motor Output W 66
Running Current (Rated) A 10.59 - 10.20 - 9.71 11.42 - 10.93 - 10.44
Power Consumption (Rated) W 2,305 - 2,305 - 2,305 2,490 - 2,490 - 2,490
Power Factor % 98.9 - 98.3 - 98.9 99.1 - 99.0 - 99.4
Starting Current A 11.7
Dimensions (H × W × D) mm 770 × 900 × 320
Packaged Dimensions (H × W × D) mm 900 × 925 × 390
Weight (Mass) kg 71
Gross Weight (Gross Mass) kg 79
Sound
Pressure
Level
H / SL dB(A) 52 / 49 52 / 49
Sound Power
Level
HdB 66 66
Drawing No. 3D066641
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
5 m