List of Functions SiENBE04-507A
2 List of Functions
1. List of Functions
Category Functions
FTKS20-35DVMW(L)
RKS20-35D(2)VMB
FTXS20-35DVMW(L)
RXS20-35D(2)VMB
Category Functions
FTKS20-35DVMW(L)
RKS20-35D(2)VMB
FTXS20-35DVMW(L)
RXS20-35D(2)VMB
Basic
Function
Inverter (with Inverter Power Control) {{
Health &
Clean
Air Purifying Filter with Bacteriostatic,
Virustatic Functions
——
Operation Limit for Cooling (°CDB)
H1
–10
~46
–10
~46
Operation Limit for Heating (°CWB) —
–15
~20
Photocatalytic Deodorizing Filter — —
Air Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control {{
Compressor
Oval Scroll Compressor — —
Titanium Apatite Photocatalytic
Air-Purifying Filter
{{
Swing Compressor {{
Rotary Compressor — — Mold Proof Air Filter {{
Reluctance DC Motor {{ Wipe-clean Flat Panel {{
Comfortable
Airflow
Power-Airflow Flap — — Washable Grille — —
Power-Airflow Dual Flaps {{ Mold Proof Operation — —
Power-Airflow Diffuser — — Heating Dry Operation — —
Wide-Angle Louvers {{ Good-Sleep Cooling Operation — —
Vertical Auto-Swing (Up and Down) {{
Timer
24-Hour On/Off Timer {{
Horizontal Auto-Swing (Right and Left) — — Night Set Mode {{
3-D Airflow — —
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) {{
Comfort Airflow Mode {{
Self-Diagnosis (Digital, LED) Display
{
H2
{
H2
3-Step Airflow (H/P Only) — —
Comfort
Control
Auto Fan Speed {{ Wiring Error Check — —
Indoor Unit Silent Operation {{
Anticorrosion Treatment of Outdoor
Heat Exchanger
{{
Night Quiet Mode (Automatic) — —
Outdoor Unit Silent Operation (Manual) {{
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
{{
Intelligent Eye {{
Quick Warming Function — { Flexible Voltage Correspondence {{
Hot-Start Function — { High Ceiling Application — —
Automatic Defrosting — { Chargeless 10m 10m
Operation
Automatic Operation — { Either Side Drain (Right or Left) {{
Programme Dry Function {{ Power Selection — —
Fan Only {{
Remote
Control
5-Rooms Centralized Controller
(Option)
{{
Lifestyle
Convenience
New Powerful Operation (Non-Inverter) — —
Inverter Powerful Operation {{
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
{{
Priority-Room Setting — —
Cooling / Heating Mode Lock — —
Remote Control Adaptor
(Normal Open Contact) (Option)
{{
Home Leave Operation — —
ECONO Mode {{
DIII-NET Compatible (Adaptor) (Option)
{{
Indoor Unit On/Off Switch {{
Remote
Controller
Wireless {{
Signal Reception Indicator {{ Wired — —
Temperature Display — —
Another Room Operation — —
Note: { : Holding Functions
— : No Functions
H
1 :
H2 :
Lower limit can be extended to –15°C by cutting
jumper. (facility use only)
Digital Only