EasyManuals Logo

Daikin FTXS35DAVMW(L) User Manual

Daikin FTXS35DAVMW(L)
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
SiENBE04-507A Main Functions
Function and Control 53
1.7 NIGHT SET Mode
When the OFF timer is set, the NIGHT SET circuit automatically activates.
The NIGHT SET circuit maintains the airflow setting made by users.
The NIGHT SET
Circuit
The NIGHT SET circuit continues heating or cooling the room at the set temperature for the first
one hour, then automatically raises the temperature setting slightly in the case of cooling, or
lowers it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling Operation
Heating Operation
Timer operation
Night Set Circuit ON
+0.5°C
temperature shift
Operation stops
at the set hours
Temperature
setting + 0.5°C
Temperature
settting
0.5°C
1 hour
(R4421)
Thermostat
setting
Timer operation
Night Set Circuit ON
1 hour later
2°C
(R1362)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXS35DAVMW(L) and is the answer not in the manual?

Daikin FTXS35DAVMW(L) Specifications

General IconGeneral
BrandDaikin
ModelFTXS35DAVMW(L)
CategoryAir Conditioner
LanguageEnglish

Related product manuals