SiENBE04-507A Main Functions
Function and Control 57
1.10 Inverter POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Details of the
Control
When POWERFUL button is pushed in each operation mode, the fan speed / setting
temperature will be converted to the following states in a period of twenty minutes.
Ex.) : Powerful operation in cooling mode.
Operation mode Fan speed Target set temperature
COOL H tap + 50 rpm 18°C
DRY Dry rotating speed +
50 rpm
Normally targeted
temperature in dry
operation; Approx. –2°C
HEAT H tap + 50 rpm 30°C
FAN H tap + 50 rpm
AUTO Same as cooling /
heating in Powerful
operation
The target is kept
unchanged
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Stop
3. Powerful operation is OFF.
(R4606)
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Stop
3. Powerful operation is OFF.
Target temp.
Set temp.
18°C
Powerful ON
Powerful OFF
Fan
H tap
Set tap
It should be the lower limit of cooling temperature.
It counts 20 min. also in the remote control.
20min.
50rpm
(R4606)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXS35DAVMW(L) and is the answer not in the manual?

Daikin FTXS35DAVMW(L) Specifications

General IconGeneral
BrandDaikin
ModelFTXS35DAVMW(L)
CategoryAir Conditioner
LanguageEnglish

Related product manuals