Installing Daikin One+
Maximum wire distance between the Daikin One+ and the
indoor unit should not exceed 100 feet using 18 gauge wire.
Wiring communicating indoor unit to communicating
outdoor units
Connect 1, 2, C and R from the Daikin One+, to 1, 2, C and R at
the indoor unit.
Connect wires 1 and 2 from the indoor unit to 1 and 2 at the
outdoor unit.
Wiring communicating indoor unit to non-communicating
outdoor units.
Connect 1, 2, C and R from the Daikin One+, to 1, 2, C and R at
the indoor unit.
Connect wire Y1 from the indoor unit to Y1 at the outdoor unit.
1
2
R
C
Data Line 1
Data Line 2
24 volt power
24 volt common