Outer Panels Si001270EB
2 Removal Procedure
1. Outer Panels
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure Points
1
Remove the 4 screws
and lift the top panel.
The discharge grille has 4
hooks.
2
Remove the 4 screws
and remove the
discharge grille.
3
Remove the 6 screws
of the front panel.
4
Push the front panel
and lift the shield plate
to unfasten the hooks.
Top panel
(R17523)
Discharge grille
(R2679)
Front panel
(R2680)
Shield plate
(R16560)
(2) Lift the shield
plate upwards.
(1) Push the
front panel.