15
TROUBLE SHOOTING
Case Explanation
Theindoorunitgivesoutodour. This happens when smells of the room, furniture, or cigarettes are
absorbed into the unit and discharged with the airow.
(If this happens, we recommend you to have the indoor unit washed by a
technician. Consult the service shop where you bought the air conditioner.)
Theoutdoorfanrotateswhiletheair
conditioner is not in operation.
After operation is stopped:
The outdoor fan continues rotating for another 60 seconds for system protection.
While the air conditioner is not in operation:
When the outdoor temperature is very high, the outdoor fan starts
rotating for system protection.
The operation stopped suddenly.
(operationlampison)
For system protection, the air conditioner may stop operating on a sudden
large voltage uctuation.
It automatically resumes operation in about 3 minutes.
”isdisplayedontheremote
controller,andthedisplayedcontentsash
forseveralsecondswhenanoperation
button is pressed.
Whenthreeshort“beep”soundsareissued
inthecaseofwirelessremotecontroller.
The air conditioner is controlled by the central equipment.
Flashing of the displayed contents indicates that the remote controller is
invalid for control.
COOLcannotbechangedover.
Whenthedisplayshows“
(changeoverundermastercontrol),
itshowsthatthisisaslaveremote
controller.
Whenalong“beep”soundisissuedin
thecaseofwirelessremotecontroller.
Refer to page 12.
Theliquidcrystaloftheremote
controllershows
immediately
afterthepowersupplyisturnedon.
This shows that the remote controller is in normal condition.
This continues for one minute.
Thecompressorintheoutdoorunitdoes
not stop after a short heating operation.
This is to prevent oil and refrigerant from remaining in the compressor.
The unit will stop after 5 to 10 minutes.
Theinsideofanoutdoorunitiswarm
whentheunithasstopped.
This is because the crankcase heater is warming the compressor even
while the outdoor unit is stopped so that the compressor can start smoothly.
Whentheairconditionerhasnotbeenused
(thepowerhasbeenoff)foralongtime.
For protecting the mechanism, supply the power for 6 hours at rst, then
operate the air conditioner.
Warmairexitstheuniteventhoughitisoff.
Youcanfeelhotaircomingoutoftheunit.
Multiple units are operating on the same system, so if a unit in another
room is operating, some refrigerant will ow through the stopped units, too.
Calltheserviceshopimmediately.
WARNING
When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF.
Continued operation in an abnormal condition may result in troubles, electric shocks or re.
Consult the service shop where you bought the air conditioner.
Do not attempt to repair or modify the air conditioner by yourself.
Incorrect work may result in electric shocks or re.
Consult the service shop where you bought the air conditioner.
If one of the following symptoms takes place, call the service shop immediately.
Thepowercordisabnormallyhotordamaged.
Anabnormalsoundisheardduringoperation.
The safety breaker, a fuse, or the earth leakage breaker cuts off the operation frequently.
Aswitchorabuttonoftenfailstoworkproperly.
Thereisaburningsmell.
Waterleaksfromtheindoorunit.
Turn the breaker
OFF and call the
service shop.
After a power failure
The air conditioner automatically resumes operation in
about 3 minutes. You should just wait for a while.
Lightning
If lightning may strike the neighbouring area, stop
operation and turn the breaker OFF for system protection.