Outdoor Unit SiBE041010
126 Removal Procedure
5
Unfasten the hook on
the rear side.
When reassembling, make
sure to fit the hook.
6
Unfasten the hook, and
lift up the right side
panel to remove.
2. Remove the electrical
box.
1
Disconnect the
connector for four way
valve coil [S80].
2
Disconnect the
connector for overload
protector [S40].
Step
Procedure Points
(R7386)
Hook
Hook
(R7387)
Right side panel
(R7388)
[S80]
[S40]
(R7389)

Table of Contents