5
Depending on the alarm system status, the keypad will operate as follows:
1. Alarm system status: Disarmed
Detection Keypad response
Distant No response
Close Back-lighting for 10 s
(1) IMPORTANT: the message or warning beeps are issued if parameter 23 has been enabled (factory disabled).
2. Alarm system status: Totally Armed or Group to which the keypad infrared detector has been allocated Armed:
Example:
The user enters his home:
The door/window detector detects his presence and
the keypad motion detector observes a time delay
allowing the user to reach the keypad and stop the
system.
Combined triggering
A combined detector will trigger immediately if it is the first detector to be set off. It will observe a time delay before
triggering if another time-delayed detector detects something first.
In the event of intrusion via a window:
The door/window detector is not set off whereas the
keypad motion detector is immediately triggered
along with the other alerts and deterrents.
time-delayed
door/window
detector
keypad
keypad
door
window
time-delayed
door/window
detector
door
window
Detection
Infrared
detector
alarm level
Keypad response
Control panel
response
Siren response
Time-delayed
triggering of infrared
detector
(detector programmed
for time delay or
combined operation
and triggered 2
nd
)
Immediate triggering
of infrared detector
(detector programmed
for combined
operation
and triggered 1
st
)
Distant
or
close
Intrusion
• back-lighting
for 10 s
• warning message
“bip, bip, bip,
protection active” (1)
no response
loud sounding
for 90 s
loud sounding
for 90 s + strobe
flashing for 15 min
Prealarm
• back-lighting for 10 s
• series of 10 beeps (1)
loud sounding
for 15 s
loud sounding
for 15 s + strobe
flashing for 15 s
Deterrence
• back-lighting for 10 s
• series of 5 beeps (1)
series of beeps
for 5 s
series of beeps
for 5 s + strobe
flashing for 5 s
Warning
• back-lighting for 10 s
• series of 3 beeps (1)
series of beeps
for 2 s
series of beeps
for 2 s + strobe
flashing for 5 s