5
Depending on the alarm system status, the keypad will operate as follows:
1. Alarm system status: Disarmed
Detection Keypad response
Distant No response
Close Back-lighting for 10 s
(1) IMPORTANT: the message or warning beeps are issued if parameter 23 has been enabled (factory disabled).
2. Alarm system status: Totally Armed or Group to which the keypad infrared detector has been allocated Armed:
Example:
• The user enters his home:
The door/window detector detects his presence and
the keypad motion detector observes a time delay
allowing the user to reach the keypad and stop the
system.
Combined triggering
A combined detector will trigger immediately if it is the first detector to be set off. It will observe a time delay before
triggering if another time-delayed detector detects something first.
• In the event of intrusion via a window:
The door/window detector is not set off whereas the
keypad motion detector is immediately triggered
along with the other alerts and deterrents.