Display Maintenance
26
10 Display Maintenance
Service Calls
After addressing service issues on a service call, inspect the following items:
Check for loose modules.
Check for corrosion.
Check the display for signs of damage.
Check the control enclosure lters. Replace if needed.
Inspect the control system for damage.
Perform an inventory of the spare parts rack.
Have the help desk run a diagnostics check of the display. Work with the help desk to
repair any issues found during diagnostics.
Diagnostics should be free of any errors prior to leaving the site.
Annual Inspection
It is important to schedule annual maintenance visits on a digital billboard. During the
visit:
Replace ISP enclosure lters.
Inspect for loose modules.
Inspect the display for excess dust or debris.
Use the Digital Billboard Maintenance Checklist (DD3059470) to record inspection
ndings.
Note: After performing service or completing connections, replace the display
door and ensure it is attached to the safety lanyard and secured with a
screw (#10-24 X0.625 hex head, Daktronics part number HC-1554) in the
provided location on the top-right side of each door. Refer to Figure 6. Find
replacement screws in a bag in the spare parts area.