Calibration
51
To automatically adjust the modules, follow these steps:
1. Click Start. A Session Options window opens. Refer to Figure 98.
Figure 98: Calibration Session Options
2. Click Start again to open the Autoblend Calibration tool.
3. Choose a display output color from the Pattern drop-down list to view the display’s
current color calibration and evaluate the need for automatic module adjustment.
Refer to Figure 99.
4. Click Preview to start the automatic calibration process. This can take a few seconds
or a few minutes depending on the size of the display. A progress bar shows the
status of the calibration process. Review the changes made to the display.
5. Click one or more of the following options
after adjusting the modules:
a. Click Store to save the newly changed
calibration values.
b. Click Clear Preview to clear the
recently made changes (all changes
made since the last Store).
c. Click Clear Stored to delete the
stored manual module calibration. If
the display is camera calibrated, this
will become the default, otherwise
the settings will revert to the factory
default.
Note: After clicking Clear Stored, a conrmation prompt opens since this
action removes the stored manual calibration from the entire display.
Press Yes to clear the manual calibration settings, or No to exit. Refer to
Figure 100.
Figure 100: Clear Stored Calibration Settings
Figure 99: Output Color Patterns