71 Spyder2 4k User’s Manual
03-032-10195-04 DALSA
Cod
e
Command Short
Form
Parameters Description
36 set_pretrigger
sp i
Set the pretrigger to a value
from 0 or 15.
37 set_prnu_coeff
spc i i
Set the PRNU coefficient. The
first parameter is the pixel
number within the range 1 to
8192. The second parameter is
a specified value within the
range 0 to 511where:
512
1
i
PixelPRNU
=
38 set_subtract_background
ssb t i
Subtracts the input value from
the output signal. The first
parameter is the tap selection 1
to 2, or 0 for all taps. The
second parameter is the
subtracted value range from 0
to 511.
39 set_sync_frequency
ssf i
Sets the line rate, in exposure
mode 2, to a value from
1000Hz to camera's maximum
line rate. Value rounded
up/down as required.
40 set_system_gain
ssg t i
Set the digital gain. The first
parameter is the tap selection 1
to 2, or 0 for all taps. The
second parameter is a gain
value is specified from 0 to
511.
41 set_upper_threshold
sut i
Set upper threshold to a value
from 0 to 255 in 8-bit data
modes, and 0 to 1023 in 10-bit.
42 set_video_mode
svm i
Switch between calibrated and
uncalibrated modes:
0: Uncalibrated video,
deactivate video correction
1: Calibrated video, activated
correction
2: Test pattern
43 verify_temperature
vt
Check the internal
temperature of the camera.
44 verify_voltage
vv
Check the camera voltages and
return OK or fail.
45 warning_enable_disable
wed [i] [i]
Read enable/disable status of
all defined monitoring tasks.
Optionally, the first parameter
selects a monitoring task and
the second parameter
enables/disable the selected
task.
Parameters:
i = integer
f = float
t = tap selector
s = string
x1 = pixel start
number
x2= pixel end number
[]= optional
parameter