70 Spyder2 4k User’s Manual
03-032-10195-04 DALSA
Cod
e
Command Short
Form
Parameters Description
29 set_digital_offset
sdo t i
Subtracts the input value from
the video signal prior to the
PRNU correction. The first
parameter is the tap selection 1
to 2, 0 for all taps. The second
parameter is the offset in a
range from 0 to 511. Use in
calibrated mode only.
30 set_exposure_mode
sem i
Set the exposure mode:
1: Internal SYNC and PRIN,
max line rate and exposure
time, factory setting
2: Internal SYNC and PRIN,
programmable line rate and
exposure time using
commands ssf and set
3: External SYNC, internal
PRIN, maximum exposure
time
4: Smart EXSYNC
5: External SYNC and PRIN
6: External SYNC, internal
PRIN, programmable
exposure time
31 set_exposure_time
set f
Set the exposure time in
exposure mode 2 or 6. Value
will be a floating point number
in µsecs
32 set_fpn_coeff
sfc i i
Set the FPN coefficient. The
first parameter is the pixel
number within the range 1 to
8192. The second value is a
specified value within the
range 0 to 127.
33 set_gain
sg t f
Set the analog gain. The first
parameter is the tap selection 1
to 2, 0 for all taps. The second
parameter is a gain value
specified from –10 to 10. A
gain value of 0 sets the camera
to its nominal gain.
34 set_lower_threshold
slt i
Set the lower threshold to a
value from 0 to 255 for 8-bit
data modes, and 0 to 1023 for
10-bit.
35 set_netmessage_mode
snm i
Enable/disable camera
messages unrelated to the
executed network command:
0: Enable messages, default
1: Disable messages
Parameters:
i = integer
f = float
t = tap selector
s = string
x1 = pixel start
number
x2= pixel end number
[]= optional
parameter