9 Spyder2 4k User’s Manual
03-032-10195-04 DALSA
1. Measured at front plate. The corresponding ambient temperature range with still
air is 0 °C – 37 °C.
2. Due to FPN/PRNU correction calculations, certain digital numbers will be
unavailable when outputting 10 bits with FPN/PRNU correction.
3. Measurements taken at maximum line rates.
4. Exposure control enabled to set the maximum integration time to 200 µs.
5. Refer to Appendix D for a DC Offset de-rating curve.
Figure 2: Spyder2 4k Responsivity
Spyder2 4k Responsivity @ 10 dB
Wavelength (nm)
Responsivity [DN/(nJ/cm )]
2
400 500 600 700 800 900 1000
0
13
26
38
51
64
77