4.2. Secondary safety at Z5156 Q Flying adapter
WARNING!
Do not connect the secondary safety to the centre socket
[CR] (Fig. 30) at the back of the cabinet. This socket is
intended for horizontal aiming of an array and limited to a
load of 50 kg (110 lb).
[R2]
[R4]
[CR]
Fig. 30: Sockets for secondary safety
The secondary safety should be applied to the top cabinet of the array.
Use two Z5048 Flying pins 10 mm connected to the sockets [R2] at the
rear of the cabinet or two Q9032 M10 Safety eye bolts attached to the
threaded inserts [R4] on both sides of the cabinet, passing the steel rope
through the Flying pins or the Safety eye bolts and attaching it to the
securing pickup point.