Danfoss ECtemp™ Smart
Installation Guide10
Follow the steps below to mount the thermostat:
1. Unpack thermostat
2. Connect the thermostat according to the connection
diagram.
The screen of the heating
cable must be connected to
the earth conductor of the
power supply cable by using
a separate connector.
Note: Always install the oor sensor in a conduit in
the oor.
3. Fasten the thermostat rmly to a ush mounted wall
box or an exterior wall box by driving the screws
through the holes in each side of the thermostat.
4. Add the frame before assembling
of top part to the snap locks/bot-
tom part.
5. Click the front part module in
place. Pay attention, in relation to
IP21
T30
Mains
220-240V~
50-60 Hz
Maximum
Load 16 (1) A
Sensor
NTC
Danfoss A/S
Nordborgvej 81
6430 Nordborg
Denmark
NLL
L
O
A
D
N
L
O
A
D
Standby maximum 0.4 Watt