Danfoss ECtemp Touch
7Installation Guide
Do not place the thermostat in a way that it will be
exposed to direct sunlight.
Note: A oor sensor enables a more accurate
temperature control and is recommended in all oor
heating applications and mandatory under wooden
oors to reduce the risk of over-heating the oor.
Place the oor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
Equally distant and >2cm from two heating cables.
The conduit should be ush with the oor surface -
countersink the conduit if necessary.
Route the conduit to the connection box.
The bending radius of the conduit must be min 50mm.