Page #9 background image
Programming Tools
Examples
Manual operation with
buttons (Direct Access)
The controller can be configured in four ways:
Using:
• KoolProg and KoolKey as Gateway
• KoolKey as Copy key
• KoolKey with Docking station
• Buttons on the front panel of the controller.
Changing the Desired Temperature Set point:
1. The display shows the current temperature.
2. Press "up/down" to access set point.
3. Press "up/down" to adjust set point.
After 30 seconds, the display automatically
reverts to showing the current temperature
Turning ON/OFF the ECO Function:
1. Press "ECO".
The green "ECO" symbol is lit when in "ECO"
mode.
Turn ON/Off the Light:
1. Press the "Light" button.
Acknowledging Alarms:
1. Display Flashing the alarm message.
2. Press any button to acknowledge.
Password protection:
1. Press "^" and "v" together and hold 5 seconds
to access the menu.
2. The display shows "PAS" (only if configured for
password protection).
3. Press "OK".
4. Press "^" / "v" to the code.
5. Press "OK".
Password protection on three levels:
1. Level 1: "shop" (daily use by shop personnel).
2. Level 2: "ser" (service technician).
3. Level 3: "OEM" (OEM programming).
1 Press: variable direct
function, e.g.ECO”/”Night mode
Sub function: back
1 Press: variable direct
function, e.g. light
Sub function: OK
1 Press: temperature set point
Sub function:up
1 Press: temperature set point
Sub function:down
Changing a Parameter
Some parameters may be hidden to you.
Your access level will determine which
parameters you can view and edit:
1. Press "^" and "v" together and hold 5 seconds
to access the menu.
2. First parameter group is shown "tHE".
3. Press "^" and "v" to find the desired group.
4. Press "OK".
5. First parameter is shown.
6. Press "^" and "v" to find the desired
parameter.
7. Press "OK".
8. Press "^" and "v" to find the desired setting.
9. Press "OK".
After 30 seconds, the display automatically
reverts to showing the current temperature.
Or Press 2 x "Back".
NOTE:
Incorrect parameter settings can lead
to inadequate cooling, excessive energy
consumption, unnecessary alarms and in the
case of temperature-sensitive food storage,
breaches in food hygiene principles and
regulations.
Only a trained operator should make changes to
parameters.
Operation
All these tools are supplied separately.
For technical literature and further information,
please contact your local Danfoss representative.
User Guide | ERC 112 Refrigeration Controller
© Danfoss | DCS (vt) | 2019.07 BC200686422115en-000802 | 9

Other manuals for Danfoss erc 112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss erc 112 and is the answer not in the manual?

Danfoss erc 112 Specifications

General IconGeneral
TypeElectronic Refrigeration Controller
Supply Voltage230 VAC
Relay Outputs3
ApplicationRefrigeration
Digital Inputs1
Protection ClassII
Sensor TypeNTC
Storage Temperature-20°C to 70°C