The controller can be controlled in three ways:
Using "Software tool", the Danfoss Docking 
Station or manually by means of the buttons on 
the front panel.
"Software tool" is licenced Danfoss software 
offering easy parameter set up via a USB gateway. 
This software is supplied separately; 
for technical literature and further information, 
please contact your local Danfoss representative.
Docking station is supplied separately.
For further information, please contact your local 
Danfoss representative.
Changing the Desired Temperature Set point:
1. The display shows the current temperature.
2. Press "up/down" to access set point.
3. Press "up/down" to adjust set point.
After 30 seconds, the display automatically 
reverts to showing the current temperature
Turning ON/OFF the ECO Function:
1. Press "ECO".
The green "ECO" symbol is lit when in "ECO" 
mode.
Turn ON/Off the Light:
1. Press the "Light" button.
Acknowledging Alarms:
1. Display Flashing the alarm message.
2. Press any button to acknowlege.
Password protection:
1. Press "up/down" and hold 5 seconds to access 
the menu.
2. The display shows "PAS".
3. Press "OK".
4. Press "Up/Down" to the code.
5. Press "OK".
Password protection on three levels:
1. Level 1: "shop" (daily use by shop personnel).
2. Level 2: "ser" (service technician).
3. Level 3: "OEM" (OEM programming).
1 Press:  variable direct
function, e.g. “ECO”/”Night mode”
Sub function: back
1 Press:  variable direct
function, e.g. light
Sub function: “OK”
1 Press: temperature set point
Sub function: “up”
1 Press: temperature set point
Sub function: “down”
Changing a Parameter
Some parameters may be hidden to you.  
When scrolling through menus, the parameters 
available will have been pre-determined using  
"Software tool". 
Your access level will determine which 
parameters you can view and edit:
1. Press "up/down" and hold 5 seconds to access 
the menu.
2. First parameter group is shown "tHE".
3. Press "up/down" to find the desired group.
4. Press "OK".
5. First parameter is shown.
6. Press "up/down" to find the desired 
parameter.
7. Press "OK".
8. Press "up/down" to find the desired setting.
9. Press "OK".
After 30 seconds, the display automatically 
reverts to showing the current temperature.
Or Press 2 x "Back".
NOTE:
Incorrect parameter settings can lead 
to inadequate cooling, excessive energy 
consumption, unnecessary alarms and in the 
case of temperature-sensitive food storage, 
breaches in food hygiene principles and 
regulations.
Only a trained operator should make changes to 
parameters.