Alarm code
In an alarm situation the display will alternate between readout of the actual air temperature and readout of the
alarm codes of active alarms. Various alarm codes and their descriptions are as below.
Table 37: Alarm codes
Air temperature sensor is defect or electrical connection is lost
S5 Evaporator sensor is defect or electrical connection is lost
Sc Condenser sensor is defect or electrical connection is lost
Air temperature in cabinet is too high
Air temperature in cabinet is too low
Supply voltage is too high (compressor protection)
Supply voltage is too low (compressor protection)
Condenser temp. too high - check air ow
Condenser temp. too high - manual reset of alarm required
(1)
Door has been open for too long
External alarm from DI input
Control has been stopped by "r12 Main switch"
(1)
The condenser block alarm can be reset by setting r12 Main switch OFF and ON again or by powering down the controller.
(1)
The condenser block alarm can be reset by setting r12 Main switch OFF and ON again or by powering down the controller.