FCM 300 Series
11
MG.03.B6.02 - VLT is a registered Danfoss trademark
Selection of FC motor
■ Ordering info for Frames and Flanges
Flange size according to IEC ref. FFxxx (Dimension M in chapter 6)
S: Available as standard shaft
A: Available as an alternative with specially elongated shaft to provide standard shaft for frame
B: Available as an alternative with standard shaft for frame, requiring no modification
Frame sizes and the corresponding flange sizes for different mounting versions
Type Motor frame size Mounting version Flange size, Flange size, Flange size
standard (S) alternatives (A) alternatives (B)
4 pole 2 pole [mm] [mm] [mm]
FCM 305 080MG 080MF
B5/B35 165 85/100/115/130
B14/B34 100 75/85/115/130/165
B5/B35 165 85/100/115/130
FCM 307 080MR 080MF
B14/B34 100 75/85/115/130/165
FCM 311 090LK 090SJ
B5/B35 165 100/115/130 215
B14/B34 115 85/100/130/165
B5/B35 165 100/115/130
FCM 315 090LT 090SJ
B14/B34 115 85/100/130/165
FCM 322 100LR 100LJ
B5/B35 215 165
B14/B34 130 165 85/100/115/215
B5/B35 215 165
FCM 330 100LT 100LM
B14/B34 130 165 85/100/115/215
FCM 340 112MT 112MS
B5/B35 215 115/130/165
B14/B34 130 165 85/100/115/215
FCM 355 132SJ 132SF
B5/B35 265 215
B14/B34 165 215
B5/B35 265 215
FCM 375 132MT 132SJ
B14/B34 165 215
■ Ordering info for inverter box position and drain hole position.