FCM 300 Series
MG.03.B6.02 - VLT is a registered Danfoss trademark16
Terminal arrangement (for installation see quick setup, MG.03.Fx.xx)
Technical data
Screen
Externals:
- Enclosure ............................................................................................................................. IP 55 (IP56, IP66)
- Vibration test ........................................................................................................... (IEC 68 see page 85) 1 g
- Max. relative humidity ................................................... 93 % +2 %, -3 % (IEC 68-2-3) for storage/transport
- Ambient temperature .......................................................................Max. 40°C (24-hour average max. 35°C)
Derating for high ambient temperature, see chapter 10.
- Min. ambient temperature in full operation .................................................................................................0°C
- Min. ambient temperature at reduced performance.............................................................................. -10°C
- Temperature during storage/transport.....................................................................................-25 - +65/70°C
- Max. altitude above sea level .............................................................................................................. 1000 m
Derating for air pressure, see chapter 10.
- EMC standards applied, Emission...................................EN 50081-1/2, EN 61800-3, EN 55011, EN 55014
Immunity ................... EN 50082-2, EN 61000-4-2, IEC 1000-4-3, EN 61000-4-4
EN 61000-4-5, ENV 50140, ENV 50141
- Safety standards applied, ............................................................................ EN 60146, EN 50178, EN 60204
UL508
Protection:
Thermal overload protection of motor and electronics.
Monitoring of the intermediate circuit voltage ensures that the inverter cuts out if the intermediate circuit
voltage gets too high or too low.
If a mains phase is missing, the inverter will cut out when a load is placed on the motor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FCM 300 Series and is the answer not in the manual?

Danfoss FCM 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelFCM 300 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals