Register Parameter Name Description
User
Level
Min Value Max Value
Default
Value
Unit/
Type
Read/
Write
Modbus
Function
Code
Modbus
Data Type
Persistent
Yes/No
8116 ValveSetpoint
Temperature
threshhold for the
opening of the main
purge valve
0 -2147483648 2147483647 0 °C
Read
only
3 Short No
8117 ValveClose
Temperature
threshhold for the
closing of the main
purge valve
0 -2147483648 2147483647 0 °C
Read
only
3 Long No
8119 Event1
Purge cycle event -
counts the minutes
that the purge valve
has been open on a
finished cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8121 Event2
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8123 Event3
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8125 Event4
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8127 Event5
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8129 Event6
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8131 Event7
Purge cycle event -
counts the accumative
minutes that the
purge valve has been
open on a finished
cycle
0 -3276,8 3276,7 0 Minutes
Read
only
3 Long No
8133 PP1
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8135 PP2
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8137 PP3
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8139 PP4
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8141 PP5
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8143 PP6
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8145 PP7
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8147 PP8
The time percentage
for this purge point
0 -32768 32767 0 %
Read
only
3 Long No
8149 Val1
This indicates if the
purge point is active
0 -32768 32767 0 N/A
Read
only
3 Short No
8150 Val2
This indicates if the
purge point is active
0 -32768 32767 0 N/A
Read
only
3 Short No
8151 Val3
This indicates if the
purge point is active
0 -32768 32767 0 N/A
Read
only
3 Short No
8152 Val4
This indicates if the
purge point is active
0 -32768 32767 0 N/A
Read
only
3 Short No
8153 Val5
This indicates if the
purge point is active
0 -32768 32767 0 N/A
Read
only
3 Short No

Other manuals for Danfoss IPS 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss IPS 8 and is the answer not in the manual?

Danfoss IPS 8 Specifications

General IconGeneral
BrandDanfoss
ModelIPS 8
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals