User Guide | Intelligent Purging System (IPS 8) for Ammonia - Technical data, installation and use
4 | BC344024774466en-000201
© Danfoss | DCS (ms) | 2021.03
Ordering
Unit
Code number
Danfoss Intelligent Purging System IPS 8 60Hz unit 084H5003
Accessories/Spare parts Accessory Spare part Code
Flange blind blank incl Bolts, nuts and Gaskets* x
084H5053
SV3 Float Valve x
027B2023
ICF 15-4 solenoid, DIN Butt weld 15mm ½ inch x
027L4543
ICF 15-4 solenoid, ANSI Socket weld 15mm ½ inch x 027L4538
ICF 15-4 solenoid, ANSI Butt weld 15mm ½ inch x 027L4602
Welding Flange incl Bolts, nuts and Gaskets x 084H5061
Purger solenoid kit (Armature, tube, Sealing, Orifice, Filter insert) x 084H5051
Solenoid coil, 24V DC x x 018F6968
Coil 93 – 121 V AC, 60 Hz, 16 W/29 VA - for field purge solenoid valves x 018F6813
Coil 110 – 120 V AC, 60 Hz, 16 W - for field purge solenoid valves x 018F4112
Coil 110 – 120 V AC, 60 Hz, 16 W - for field purge solenoid valves x 018F4113
PSU, 24V DC - optional for powering purge points x x 080Z0055
Restrictor, purge line
x 084H5054
UL compressor Cranck case heater
x 084H5065
UL condenser coil assy incl screws
x 084H5066
UL fan motor for condenser Incl fan grid and screws
x 084H5060
UL extraction Fan
x 084H5062
UL Air grid with filter (1 piece)
x 084H5063
Pre-programmed MCX 15
x 084H5052
Pressure transmitter evaporator, soldered (AKS 32R)
x 060G3552
Compressor including Start relay box and Start and Run Capacitor
x 104L2897
Compressor Hi-temp sensor
x 084N2003
Expansion valve, R452A
x 068U3881
Sight glass
x 014-0191
Pressure transmitter - R717, Threaded, AKS2050
x 060G5750
Thermostat for crankcase heater control
x 060L111166
Temperature sensor - R717, AKS 21M
x 084N2003
Pressure switch for Fan
x Contact Danfoss
Pressure safety switch
x Contact Danfoss
* For closing system flange during system pressure testing
Technical data
Supply voltage 230 V +/-10% AC, 1ph, 60Hz
Voltage range for field
1
) connected solenoid coils: 115 V +/- 10% AC 60Hz
Maximum Current Rating of Overcurrent Protection (MOP) 15A
Minimum Circuit Ampacity (MCA) 6,85A
Power consumption max. 1.25 kW
Short-circuit current rating SCCR 18kA
Temperature range ambient -10 °C – 43 °C (14 °F – 109 °F)
Temperature range transport/storage -30 °C to +60 °C (-22 °F to 140 °F)
Enclosure - Electrical panel Type 12
Weight max. 125 kg (276 lbs)
Dimensions (LxWxH) 1051 x 441 x 703 mm (41.4 x 17.4 x 27.7 inches)
Purger refrigerant R452A 900 gram (31.7 oz)
Max. operating pressure (PS) R452A 28 bar (406 psi)
System refrigerant R717
Max. operating pressure R717 40 bar (580 psi)
Operating temperature R717 -40 °C to +60 °C (-40 °F to 140 °F)
Note:
All Spare part items are parts already built-in to
the IPS 8.
(084H5061, Welding Flange incl Bolts, nuts and
Gaskets are included with IPS 8, not built-in).
1
) Field connected coils on Digital Output:
Accessory parts may possible be used at
installation along with the IPS 8.
Description Field connected valves
Q6, COM6, OUT6 YV ICFD Valve
Q7, COM7, OUT7 Y1 Valve
Q8, COM8, OUT8 Y2 Valve
Q9, COM9, OUT9 Y3 Valve
Q10, COM10, OUT10 Y4 Valve
Description Field connected valves
Q11, COM11, OUT11 Y5 Valve
Q12, COM12, OUT12 Y6 Valve
Q13, COM13, OUT13 Y7 Valve
Q14, COM14, OUT14 Y8 Valve