Important
The nodeID set in the WAKE_UP_INTERVAL_SET command must be for a permanently listening
device which reponds to the commands sent from living connect®. This means PC's with USB
sticks will only work if the PC is never turned off. If the controller is turned off for extended peri-
odes, living connect® will use the batteries too fast.
To preserve battery - Wake_Up_intervals should not be set to less than 5 min. Increasing the
time between intervals will increase battery life but can reduce user satisfaction due to long re-
action times.
Although living connect® supports single commands, multi commands must always be used to
ensure two years battery lifetime.
If multiple thermostats are installed in the same room it is important that the controller ensures
that they all have the same schedule and the same setpoint.
In order to ensure proper routing with battery operated devices, the controller must support
SUC.
living connect® and Z-
Wave repeaters
living connect® may benefit if more mains powered Z-Wave devices are added to a Z-Wave network.
Mains powered Z-Wave devices improve the reliability of a Z-Wave network as they can act as re-
peaters and thus provide alternate routes for communication.
Implemented Z-Wave de-
vice classes
Z-Wave Device Classes Device Class Implemented
Generic Device GENERIC_TYPE_THERMOSTAT
Specific Device SPECIFIC_TYPE_SETPOINT_THERMOSTAT
Supported and controlled
Z-Wave command classes
Z-Wave Command Classes Supported Description
COMMAND_CLASS_BATTERY Get current battery status of living connect®.
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE Control a temperature offset to the ther-
mostat setpoint of living connect®. The tem-
perature offset is defined by schedules and
schedule overrides.
COMMAND_CLASS_CLOCK Set or get the current living connect® clock.
COMMAND_CLASS_MANUFACTURER_PROPRIETARY Special command used for communication
with a Danfoss Link system.
COMMAND_CLASS_MANUFACTURER_SPECIFIC Get manufacturer ID of system.
COMMAND_CLASS_MULTI_CMD A special Z-Wave command used by living
connect® to encapsulate multiple com-
mands in one command and thereby con-
serve battery life.
COMMAND_CLASS_PROTECTION Set or get living connect® local protection
mode.Possible local protection values are:
0 = no protection
2 = fully locked (tamperproof)
COMMAND_CLASS_THERMOSTAT_SETPOINT Set or get current thermostat setpoint of
living connect®.Heating setpoint is the only
supported setpoint type.
COMMAND_CLASS_VERSION Get version of product and command
classes.
COMMAND_CLASS_WAKE_UP A special Z-Wave command used by living
connect® to synchronize communication
with its controller.
Data Sheet living connect®, Z-Wave Certified Electronic Radiator Thermostat
Danfoss Heating Solutions VDHMB202 © Danfoss 09/2011 5

Other manuals for Danfoss living connect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss living connect and is the answer not in the manual?

Danfoss living connect Specifications

General IconGeneral
TypeElectronic Radiator Thermostat
Power Supply2 x AA batteries
Communication ProtocolZ-Wave
DisplayLCD
Battery LifeUp to 2 years
Weight177 g (including batteries)
Temperature Range4°C to 28°C
Operating Temperature0°C to 40°C
CompatibilityZ-Wave systems
Remote ControlYes