Parameter Conditions for value changes
P3245 Set to match presence of redundant WAS signal
P3244 Set to match type of WAS signal: Analog, CAN, or None
P3246 Enable only if using uncompensated Analog WAS
P3247 Enable only if using uncompensated Analog WAS
P3250 Vehicle speed must be below this threshold to allow auto-guidance or AUX device to be enabled (speed measured in
km/h)
P3251 Vehicle speed must be below this threshold to allow for switching steering wheel programs (speed measured in km/h)
P3252 Vehicle speed must be above this threshold to use auto-guidance
P3253 PVED-CLS will go into safe-state mode if vehicle speed is above this threshold
P3241 Set to match presence of Safe On-Road Switch and electric architecture
P3239 Set to match presence of AUX device
P3240 Set to match type of AUX device
P3254 Set to IMD if using EHi-H
Approve the parameters by following the steps in PVED-CLS parameter acceptance on page 8.
Application Guide
PVED-CLS startup guide
Parameter setting
10 |
©
Danfoss | October 2018 AB285975085591en-000101

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals