EasyManuals Logo

Danfoss Secop 105N9502 User Manual

Danfoss Secop 105N9502
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16
MANUAL
FRCC.ES.011.A1.02
TROUBLESHOOTING
1. Parameter De nition Files are not imported.
Solution: The Parameter De nition File contains the parameter data and settings speci c to
one type and version of Secop controller.
For some controllers, the Parameter De nition File must be imported. For others, the software
will automatically obtain the Parameter De nition File from the controller electronics.
When a Parameter De nition File import is required, the system will make a request via a
dialog in the software.
When required, the Parameter De nition File is available from the supplier on a CD or as a
le attachment via email.
2. Product Keys are not installed.
Solution: The Product Key is an alphanumeric code, which is speci c to one type and version
of Secop controller. The user must enter the Product Key to gain access to the Tool4Cool®
LabEdition functions for the Secop controller.
The user access level is coded into the Product Key, de ning which parameters and level of
the controller the user is entitled to access. For user access at a di erent level, a new Product
Key is required.
A separate Product Key is required for every individual controller type and version to be connected
to a network.
The Product Key is available from the supplier of the application.
3. Polarity on RS485 network interchanged.
Solution: Check your wiring.
4. Addressing on Modbus nodes not di erent to zero.
Solution: Check addressing of individual network nodes.
5. Mismatch in address range in Tool4Cool® and Modbus nodes.
Solution: Check addressing of individual network nodes.
6. Double addressing of Modbus nodes.
Solution: Check addressing of individual network nodes.
The message “please install driver for new hardware appears when connecting the gateway to
the computer.
Solution: The Secop Bluetooth® Gateway operates on a driver which is normally installed as
standard. Please contact the computer supplier to obtain a driver.
LED2 Sequence Meaning
LED  ashes red for approx. 3 seconds in short,
rapid bursts
...............
RS485 Bluetooth® gateway begins Slave mode
operation
Error Message
Top Causes of Errors
LED2 is  ashing red