Danfoss Heating
27
Pairing 
Failed
When first installed the startup Wizard will include 
the pairing of the TPOne-S and the Receiver.  If this 
function was not completed correctly or failed due 
to unreliable connection then this warning will be 
shown.  Manual pairing can be made by selecting 
this option in the installer menu. 
Important Note: Ensure that there are no large 
metal objects, such as boiler cases, other large 
appliances or mirrors in line of sight between 
the transmitter and receiver as these will prevent 
communication between the TPOne-S and 
receiver. 
Frost Risk This will be displayed if the TPOne monitors a 
temperature of below 5
o
C.  TPOne will call for 
heat if this occurs but if the heat source is faulty 
then risk of frost damage may still occur.  The 
heating system should be checked to confirm it is 
operating correctly
Low Heat If set mode temperature is not reached within 
2 hours then TPOne will warn of Low Heat.  The 
heating system should be checked to confirm it is 
operating correctly
Service Due Where the TPOne Service Interval timer has been 
set this warning will be shown when the timer has 
expired.  Contact the property owner or landlord 
to arrange the boiler safety mainantance.
see page 21
Heat 
Reduced
Where the TPOne Service Interval timer has been 
set this warning will show after the timer has 
expired and will indicate that heating has been 
reduced for your safety until a boiler service has 
been completed.  Contact the property owner or 
landlord to arrange the boiler safety mainantance.
see page 21
Sensor Fail If the TPOne in-built temperature sensor is 
measuring outside it’s operational parameters 
then it may have failed.  If this warning cannot be 
reset then contact your service provider for advice.