VL 5000 Crane
Appendix
Control Word in Crane Profile
C
ontrol word in Crane profile (parameter
512 = crane profile)
The control word is used for sending commands from
a master, eg. a PC, to a slave (frequency converter).
Bit Bit = 0 Bit = 1
00 Load contact 1
inverse
No function
01 Load contact 2
inverse
No function
02 No function Positioning
03 Coasting inverse No function
04 Quick stop inverse No function
05 Ramp stop Start lowering
06 Ramp stop Start hoisting
07 No function Reset
08 No function
09 Gear low Gear high
10 Data not valid Data valid
11 No function Relay 01 activated
12 No function Relay 04 activated
13 No function
14 No function
15 No function
NB!:
In Crane profile bit 04 Q stop is the only choice
for logic OR, logic AND and logic BUS.
B
it 00, Load contact 1 inverse/No function
Bit 00 = "1" means no speed reduction.
B
it 01, Load contact 2 inverse/No function
Bit 01 = "0" leads to further descreased speed (
parameter 702) if bit 00 = "0". Otherwise it leads to
a Trip. Bit 01 = "1" means no speed reduction.
Bit 00 Bit 01
Load high 0 0
Load low 0 1
Tri p 1 0
No
function
11
Bit 02, No function/Positioning
Makes the motor turn with reduced speed
according to parameters 106, Motor Nominal
Speed, and 205, Max. reference.
Bit 02 = "0" means no reduced speed. Bit 02
= "1" means reduced speed.
B
it 03, Coasting inverse/No function
Please refer to Control word in FC profile.
B
it 04, Quick stop inverse/No function
Please refer to Control word in FC profile.
B
it 05, No function/Start lowering
Makes the motor turn to lower the load opposite of the
direction set in parameter 707, Hoist direction.
Bit 05 = "0" leads to a stop if bit 06 = "0". Bit 05 = "1"
leads to start if bit 06 = "0". Otherwise it leads to a stop.
Bit 05 Bit 06
Stop 0 0
Stop 1 1
Hoisting 0 1
Lowering 1 0
Bit 06, No function/Start hoisting
Makes the motor turn to hoist the load according to the
direction set in parameter 707, Hoist direction.
Bit 06 = "0" leads to a stop if bit 05 = "0". Bit 06 = "1"
leads to start if bit 05 = "0". Otherwise it leads to a stop.
B
it 07, No function/Reset
Please refer to Control word in FC profile.
B
it 09, Gear low/Gear high
Enables gear low or high. Bit = "0" is low
gear. Bit = "1" is high gear.
B
its 10-12
Please refer to Control word in FC profile.
MG.50.N4.02 - VLT is a registered Danfoss trademark
99