EasyManua.ls Logo

Danfoss VLT 5072 - Page 48

Danfoss VLT 5072
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL 5000 Crane
Programming
PNU Parameter Range Factory setting Changes Unit Conversion Data Protection
#
4xx
description
Application functions
during
operation
index index type level
400 Brake function/over-
voltage control
Resistor Yes 0 0 5 1
401 Brake resistor, ohm 0 - 500 Depends on unit Yes 23 -1 6 1
402 Brake power limit, kW 0 - 1000kW 0 kW Yes 9 2 6 1
403 Power monitoring Warning Yes 00 51
404 Brake check Off Yes 00 51
405 Reset mode Manual reset Yes 0 0 5 1
421 Speed PID filter time 1 - 20 ms 3.2 ms Yes 4 -4 6 1
Parameter group 5xx, see serial communication!
NB!:
In parameter 512 it is possible to shift between
crane profile and FC profile!
PNU Parameter Factory setting Changes Unit Conversion Data Protection
#
6xx
description
Service functions
during
operation
index index type level
600 Operation data: Operating hours No 4 74 7 2
601 Operation Data: Running hours No 4 74 7 2
602 Operation Data: kWh counter No 8 2 7 2
603 Operation Data: Power ups No 0 0 6 2
604 Operation Data: Over temps No 0 0 6 2
605 Operation Data: Over volts No 0 0 6 2
615 Fault log: Error code No 0 0 5 2
616 Fault log: Time No 0 -1 7 2
617 Fault log: Value No 0 0 3 2
618 Reset of kWh counter Do not reset Yes 0 0 5 1
619 Reset of hours-run counter Do not reset Yes 0 0 5 1
620 Operating mode Normal function Normal operation Yes 0 0 5 1
621 Type plate: VLT type No 0 0 9 2
622 Type plate: Power section No 0 0 9 2
623 Type plate: VLT ordering number No 0 0 9 2
624 Type plate: Software version
number
No 0 0 9 2
625 Type plate: LCP ID no. No 0 0 9 2
626 Type plate: Parameter database
ID no.
No 0 -2 9 2
627 Type plate: PU database ID no No 0 0 9 2
628 Type plate: Application option
type
No 0 0 9 2
629 Type plate: Application ordering
number
No 0 0 9 2
630 Type plate: Communication type No 0 0 9 2
631 Type plate: Communication
ordering number
No 0 0 9 2
639 Flash test On Yes 0 0 5 1
650 Protection level Yes 0 0 7 2
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
47

Other manuals for Danfoss VLT 5072

Related product manuals