Q3-30 Single zone int. setpoint Q3-31 Single zone ext. setpoint Q3-32 Multi zone/adv
Parameter 20-83 PID Start Speed [Hz] Parameter 6-27 Terminal 54 Live Zero Parameter 20-14 Maximum Reference/Feedb.
Parameter 20-93 PID Proportional Gain Parameter 6-00 Live Zero Timeout Time Parameter 6-10 Terminal 53 Low Voltage
Parameter 20-94 PID Integral Time Parameter 6-01 Live Zero Timeout Function Parameter 6-11 Terminal 53 High Voltage
Parameter 20-70 Closed Loop Type Parameter 20-81 PID Normal/ Inverse Control Parameter 6-12 Terminal 53 Low Current
Parameter 20-71 PID Performance Parameter 20-82 PID Start Speed [RPM] Parameter 6-13 Terminal 53 High Current
Parameter 20-72 PID Output Change Parameter 20-83 PID Start Speed [Hz] Parameter 6-14 Terminal 53 Low Ref./Feedb.
Value
Parameter 20-73 Minimum Feedback Level Parameter 20-93 PID Proportional Gain Parameter 6-15 Terminal 53 High Ref./Feedb.
Value
Parameter 20-74 Maximum Feedback Level Parameter 20-94 PID Integral Time Parameter 6-16 Terminal 53 Filter Time Constant
Parameter 20-79 PID Autotuning Parameter 20-70 Closed Loop Type Parameter 6-17 Terminal 53 Live Zero
Parameter 20-71 PID Performance Parameter 6-20 Terminal 54 Low Voltage
Parameter 20-72 PID Output Change Parameter 6-21 Terminal 54 High Voltage
Parameter 20-73 Minimum Feedback Level Parameter 6-22 Terminal 54 Low Current
Parameter 20-74 Maximum Feedback Level Parameter 6-23 Terminal 54 High Current
Parameter 20-79 PID Autotuning Parameter 6-24 Terminal 54 Low Ref./Feedb.
Value
Parameter 6-25 Terminal 54 High Ref./Feedb.
Value
Parameter 6-26 Terminal 54 Filter Time Constant
Parameter 6-27 Terminal 54 Live Zero
Parameter 6-00 Live Zero Timeout Time
Parameter 6-01 Live Zero Timeout Function
Parameter 4-56 Warning Feedback Low
Parameter 4-57 Warning Feedback High
Parameter 20-20 Feedback Function
Parameter 20-21 Setpoint 1
Parameter 20-22 Setpoint 2
Parameter 20-81 PID Normal/ Inverse Control
Parameter 20-82 PID Start Speed [RPM]
Parameter 20-83 PID Start Speed [Hz]
Parameter 20-93 PID Proportional Gain
Parameter 20-94 PID Integral Time
Parameter 20-70 Closed Loop Type
Parameter 20-71 PID Performance
Parameter 20-72 PID Output Change
Parameter 20-73 Minimum Feedback Level
Parameter 20-74 Maximum Feedback Level
Parameter 20-79 PID Autotuning
Table 2.4 Q3-3 Closed-loop Settings
How to Programme
VLT
®
HVAC Drive FC 102
20 Danfoss A/S © 03/2015 All rights reserved. MG11CE02
22

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals