EasyManua.ls Logo

Danfoss VLT Brake Resistor MCE 101

Danfoss VLT Brake Resistor MCE 101
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
3
4
5
130BD226.10
1 Resistor connection:
Marked RB1/RB2
Type: Phoenix G10/2
IEC: 0.5-10 mm
2
/800 V
UL: AWG 20–6/600 V
Wire Stripping: 12 mm (0.47 in)
Torque: 1.5-1.8 Nm (13.28-15.94 lb-in)
2 Temperature switch connection
Marked: T1/T2
Type: Phoenix G5/2 with screw connection
IEC: 0.2–4 mm
2
/500 V
UL: AWG 24-12/300 V
Wire Stripping: 8 mm (0.31 in)
Torque: 0.7 Nm (6.2 lb-in)
3 PE: M5
Torque 2–2.7 Nm (17.71-23.91 lb-in)
4 For temperature Switch Cable: Clamping Range: 3.5-7.0
mm (0.14-0.28 lb-in)
5 For resistor cable:
Cable gland with internal connection for braid
Clamping Range: 9.0-16.5 mm (0.35-0.65 lb-in)
Illustration 9.21 Connection Box
130BD228.10
Illustration 9.22 IP21, 3D View
Mechanical mounting (see Illustration 9.23):
Vertical with connection box down (IP21), or
Horizontal (IP20)
130BD227.11
Illustration 9.23 Mechanical Mounting
Specifications Design Guide
MG90O202 Danfoss A/S © Rev. 05/2014 All rights reserved. 95
9 9

Table of Contents

Related product manuals