EasyManua.ls Logo

Danfoss VLT FC 101 - Digital Output; Control Card, RS485 Serial Communication; Control Card, 24 V DC Output; Relay Output

Danfoss VLT FC 101
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.3.7 Digital Output
Number of digital outputs 4
Terminals 27 and 29
Terminal number 27, 29
1)
Voltage level at digital output 0–24 V
Maximum output current (sink and source) 40 mA
Terminals 42 and 45
Terminal number 42, 45
2)
Voltage level at digital output 17 V
Maximum output current at digital output 20 mA
Maximum load at digital output 1 kΩ
1) Terminals 27 and 29 can also be programmed as input.
2) Terminals 42 and 45 can also be programmed as analog output.
The digital outputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
6.3.8 Control Card, RS485 Serial Communication
Terminal number 68 (P, TX+, RX+), 69 (N, TX-, RX-)
Terminal number 61 common for terminals 68 and 69
6.3.9 Control Card, 24 V DC Output
Terminal number 12
Maximum load 80 mA
6.3.10 Relay Output
Programmable relay output 2
Relay 01 and 02 01–03 (NC), 01–02 (NO), 04–06 (NC), 04–05 (NO)
Maximum terminal load (AC-1)
1)
on 01–02/04–05 (NO) (resistive load) 250 V AC, 3 A
Maximum terminal load (AC-15)
1)
on 01–02/04–05 (NO) (inductive load @ cosφ 0.4) 250 V AC, 0.2 A
Maximum terminal load (DC-1)
1)
on 01–02/04–05 (NO) (resistive load) 30 V DC, 2 A
Maximum terminal load (DC-13)
1)
on 01–02/04–05 (NO) (inductive load) 24 V DC, 0.1 A
Maximum terminal load (AC-1)
1)
on 01–03/04–06 (NC) (resistive load) 250 V AC, 3 A
Maximum terminal load (AC-15)
1)
on 01–03/04–06 (NC) (inductive load @ cosφ 0.4) 250 V AC, 0.2 A
Maximum terminal load (DC-1)
1)
on 01–03/04–06 (NC) (resistive load) 30 V DC, 2 A
Minimum terminal load on 01–03 (NC), 01–02 (NO) 24 V DC 10 mA, 24 V AC 20 mA
Environment according to EN 60664-1 Overvoltage category III/pollution degree 2
1) IEC 60947 parts 4 and 5.
6.3.11 Control Card, 10 V DC Output
Terminal number 50
Output voltage 10.5 V ±0.5 V
Maximum load 25 mA
Specications Quick Guide
MG18A802 Danfoss A/S © 05/2016 All rights reserved. 51
6
6

Related product manuals