[170] Homing Completed
[171] Target Position Reached
[172] Position Control Fault
[173] Position Mech Brake
[193] Sleep Mode
[194] Broken Belt Function
[198] Drive Bypass
6-93 Terminal 42 Output Min Scale
0 - 200 % *0 %
6-94 Terminal 42 Output Max Scale
0 - 200 % *100 %
6-96 Terminal 42 Output Bus Control
0 - 16384 *0
7-** Controllers
7-0* Speed PID Ctrl.
7-00 Speed PID Feedback Source
[1] 24V encoder
[6] Analog Input 53
[7] Analog Input 54
[8] Frequency input 29
[9] Frequency input 33
*[20] None
7-02 Speed PID Proportional Gain
0 - 1 *0.015
7-03 Speed PID Integral Time
2 - 20000 ms *8 ms
7-04 Speed PID Dierentiation Time
0 - 200 ms *30 ms
7-05 Speed PID Di. Gain Limit
1 - 20 *5
7-06 Speed PID Lowpass Filter Time
1 - 6000 ms *10 ms
7-07 Speed PID Feedback Gear Ratio
0.0001 - 32 *1
7-08 Speed PID Feed Forward Factor
0 - 500 % *0 %
7-1* Torque PID Ctrl.
7-12 Torque PID Proportional Gain
0 - 500 % *100 %
7-13 Torque PID Integration Time
0.002 - 2 s *0.020 s
7-2* Process Ctrl. Feedb
7-20 Process CL Feedback 1 Resource
*[0] No function
[1] Analog Input 53
[2] Analog Input 54
[3] Frequency input 29
[4] Frequency input 33
7-22 Process CL Feedback 2 Resource
*[0] No function
[1] Analog Input 53
[2] Analog Input 54
[3] Frequency input 29
[4] Frequency input 33
7-3* Process PID Ctrl.
7-30 Process PID Normal/ Inverse Control
*[0] Normal
[1] Inverse
7-31 Process PID Anti Windup
[0] O
*[1] On
7-32 Process PID Start Speed
0 - 6000 RPM *0 RPM
7-33 Process PID Proportional Gain
0 - 10 *0.01
7-34 Process PID Integral Time
0.10 - 9999 s *9999 s
7-35 Process PID Dierentiation Time
0 - 20 s *0 s
7-36 Process PID Di. Gain Limit
1 - 50 *5
7-38 Process PID Feed Forward Factor
0 - 200 % *0 %
7-39 On Reference Bandwidth
0 - 200 % *5 %
7-4* Adv. Process PID I
7-40 Process PID I-part Reset
*[0] No
[1] Yes
7-41 Process PID Output Neg. Clamp
-100 - 100 % *-100 %
7-42 Process PID Output Pos. Clamp
-100 - 100 % *100 %
7-43 Process PID Gain Scale at Min. Ref.
0 - 100 % *100 %
7-44 Process PID Gain Scale at Max. Ref.
0 - 100 % *100 %
7-45 Process PID Feed Fwd Resource
*[0] No function
[1] Analog Input 53
[2] Analog Input 54
[7] Frequency input 29
[8] Frequency input 33
[11] Local bus reference
[32] Bus PCD
7-46 Process PID Feed Fwd Normal/ Inv.
Ctrl.
*[0] Normal
[1] Inverse
7-48 PCD Feed Forward
0 - 65535 *0
7-49 Process PID Output Normal/ Inv. Ctrl.
*[0] Normal
[1] Inverse
7-5* Adv. Process PID II
7-50 Process PID Extended PID
[0] Disabled
*[1] Enabled
7-51 Process PID Feed Fwd Gain
0 - 100 *1
7-52 Process PID Feed Fwd Ramp up
0.01 - 100 s *0.01 s
7-53 Process PID Feed Fwd Ramp down
0.01 - 100 s *0.01 s
7-56 Process PID Ref. Filter Time
0.001 - 1 s *0.001 s
7-57 Process PID Fb. Filter Time
0.001 - 1 s *0.001 s
7-6* Feedback Conversion
7-60 Feedback 1 Conversion
*[0] Linear
[1] Square root
7-62 Feedback 2 Conversion
*[0] Linear
[1] Square root
8-** Comm. and Options
8-0* General Settings
8-01 Control Site
*[0] Digital and ctrl.word
[1] Digital only
[2] Controlword only
8-02 Control Source
[0] None
[1] FC Port
[2] FC USB
[3] Option A
8-03 Control Timeout Time
0.5 - 6000 s *1 s
8-04 Control Timeout Function
*[0] O
[1] Freeze output
[2] Stop
[3] Jogging
[4] Max. speed
[5] Stop and trip
8-07 Diagnosis Trigger
*[0] Disable
[1] Trigger on alarms
[2] Trigger alarm/warn.
8-1* Ctrl. Word Settings
8-10 Control Word Prole
*[0] FC prole
[1] PROFIdrive prole
[5] ODVA
[7] CANopen DSP 402
8-13 Congurable Status Word STW
[0] No function
*[1] Prole Default
[2] Alarm 68 Only
[3] Trip excl Alarm 68
[10] T18 DI status
[11] T19 DI status
[12] T27 DI status
[13] T29 DI status
[14] T32 DI status
[15] T33 DI status
[21] Thermal warning
[30] Brake fault (IGBT)
[40] Out of ref range
[60] Comparator 0
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
[65] Comparator 5
[70] Logic Rule 0
[71] Logic Rule 1
[72] Logic Rule 2
[73] Logic Rule 3
[74] Logic Rule 4
[75] Logic Rule 5
[80] SL digital out A
[81] SL digital out B
[82] SL digital out C
[83] SL digital out D
[93] Alarm68 or Alarm188
8-14 Congurable Control Word CTW
[0] None
*[1] Prole default
[2] CTW Valid, active low
[4] PID error inverse
[5] PID reset I part
[6] PID enable
8-19 Product Code
0 - 2147483647 *Size related
8-3* FC Port Settings
8-30 Protocol
*[0] FC
[2] Modbus RTU
8-31 Address
0.0 - 247 *1
8-32 Baud Rate
[0] 2400 Baud
[1] 4800 Baud
[2] 9600 Baud
[3] 19200 Baud
[4] 38400 Baud
[5] 57600 Baud
[6] 76800 Baud
[7] 115200 Baud
8-33 Parity / Stop Bits
[0] Even Parity, 1 Stop Bit
[1] Odd Parity, 1 Stop Bit
[2] No Parity, 1 Stop Bit
[3] No Parity, 2 Stop Bits
8-35 Minimum Response Delay
0.0010 - 0.5 s *0.01 s
8-36 Maximum Response Delay
0.1 - 10.0 s *Size related
8-4* FC MC protocol set
8-42 PCD Write Conguration
[0] None
[1] [302] Minimum Reference
[2] [303] Maximum Reference
[3] [341] Ramp 1 Ramp up time
[4] [342] Ramp 1 Ramp down time
[5] [351] Ramp 2 Ramp up time
[6] [352] Ramp 2 Ramp down time
[7] [380] Jog Ramp Time
[8] [381] Quick Stop Time
[9] [412] Motor Speed Low Limit [Hz]
[10] [414] Motor Speed High Limit [Hz]
[11] [590] Digital & Relay Bus Control
[12] [676] Terminal45 Output Bus Control
[13] [696] Terminal 42 Output Bus Control
[15] FC Port CTW
[16] FC Port REF
8-43 PCD Read Conguration
[0] None
[1] [1500] Operation Hours
[2] [1501] Running Hours
[3] [1502] kWh Counter
[4] [1600] Control Word
[5] [1601] Reference [Unit]
[6] [1602] Reference %
[7] [1603] Status Word
[8] [1605] Main Actual Value [%]
[9] [1609] Custom Readout
[10] [1610] Power [kW]
[11] [1611] Power [hp]
[12] [1612] Motor Voltage
[13] [1613] Frequency
[14] [1614] Motor Current
[15] [1615] Frequency [%]
[16] [1616] Torque [Nm]
[17] [1618] Motor Thermal
[18] [1630] DC Link Voltage
[19] [1634] Heatsink Temp.
[20] [1635] Inverter Thermal
[21] [1638] SL Controller State
[22] [1650] External Reference
[23] [1652] Feedback [Unit]
[24] [1660] Digital Input 18,19,27,33
[25] [1661] Terminal 53 Switch Setting
[26] [1662] Analog input 53
[27] [1663] Terminal 54 Switch Setting
[28] [1664] Analog input 54
[29] [1665] Analog output 42 [mA]
[30] [1671] Relay output
[31] [1672] Counter A
[32] [1673] Counter B
[33] [1690] Alarm Word
[34] [1692] Warning Word
[35] [1694] Ext. Status Word
8-5* Digital/Bus
8-50 Coasting Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-51 Quick Stop Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-52 DC Brake Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-53 Start Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
Appendix Operating Guide
MG07A402 Danfoss A/S © 10/2017 All rights reserved. 71
10 10

Table of Contents

Other manuals for Danfoss VLT Midi Drive FC 280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Midi Drive FC 280 and is the answer not in the manual?

Danfoss VLT Midi Drive FC 280 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Midi Drive FC 280
CategoryDC Drives
LanguageEnglish

Related product manuals