20
Preventive maintenance, cont.
Checklist (User)
- page 2
X
÷
Criteria
Acceptance: Start dehumidifier, check
that hour counter is working.
Acceptance: Start
dehumidifier, check
that MED
-counter measures the power
consumption.
Acceptance: Light in display. Display is
readable.
Acceptance: Clean, free of oil and dirt.
Acceptance: Ventilation openings are free
of dust and dirt.
Acceptance: Deformation < 5 mm
deep.
Openings between plates < 5 mm.
Acceptance: No loose or missing screws.
No obvious damages on handle. The
handle slides up and down easily. The
handle cannot slide up and down, when
thumbscrews are tightened.
Acceptance: Gaskets are complete and
without any cracks.
Acceptance: Wheels run freely
without
hindrance. No obvious damages on the
track of the wheels.
How to
Visually
Visually
Visually
Visually
Visually
Visually
Measuring tape
Manual check
Visually
Visually
Frequency
Y
Y
Y
M
M
Y
Y
Y
Y
What
Does operation hour counter work?
Does the MED
-counter work?
Display
The casing of the dehumidifier
Cleaning
Free passage through ventilation open-
ings
Deformations, cracks or fractures
Fixation and damage of handle
Gaskets and sealings
Visual
check of the wheels