52
INSTALLATION & SERVICE MANUAL FOR PROFESSIONALS
Appendix: Technical data
Appendix
Technical data
Specication Abbr. Unit RCV 320 P2
Max. ow at 100Pa
V
100Pa
m/h 320
Max. rated ow at 100Pa
V
max.nom
m/h 200
Operating range DIBt
V
DIBt
m/h 70-225
Operating range Passivhaus at 100Pa
V
PHI
m/h 70-160
EN 13141-7 reference ow at 50Pa
V
ref
m/h 140
Performance
Thermal eciency in accordance with
EN13141-7
h
SUP
% 89
Leakage (external and internal) in accordance
with EN 13141-7
L
W
(A) dB(A) <2% (Class A1)
Filters in accordance with ISO16890
class -
ISO Coarse 75% (optional
on supply: ePM1>50% )
Filters in accordance with EN779:2012 - -
G4
(optional on supply: F7)
Installation surrounding temperature
t
SURR
°C +12 to +45
Outdoor temperature without preheater
installed
t
ODA
°C -12* to +40
Outdoor temperature with preheater installed
t
ODA
°C -20 to +40
Maximum absolute humidity of extract air
x g/kg 10
Cabinet:
Dimensions (with wall bracket) w x h x d mm 600 x 603 x 548
Spigots/ducts connections Ø mm ø125 - female
Weight
kg 32
Thermal conductivity - polystyrene insulation
l
W/(mK) 0.031
Heat transition gures- polystyrene insulation U W/(m
2
K) U<1
Fire classication of the polystyrene insulation - -
DIN 4102-1 class B2
EN13501 class E
Drainage hose included Ø/length
“-m ø¾” – 1 m
Cabinet colour RAL
- no paint/ galvanized steel
Electrical
Voltage U
V 230
Max. power consumption
(without/ with preheater)
P
W 170/1070
Frequency f Hz 50
Protection class - - IP21
* The use of preheating coil is recommended when outdoor temperature is below -3°C to
ensure balanced operation.
Data sheet
RCV 320 P2 Basic

Related product manuals