DKG-205 AUTOMATIC
MAINS FAILURE UNIT
Question and Answer IconNeed help?

Do you have a question about the Datakom DKG-205 and is the answer not in the manual?

Summary

2. INSTALLATION

2.1 Introduction to the Control Panel

The control panel offers user friendliness and programmable parameters for complete control of the generating set.

2.2 Mounting the Unit

The unit is designed for panel mounting and fits into a standard panel meter opening of 140x68 mm.

2.3 Wiring the Unit

Instructions and warnings for wiring the unit, including fuse requirements and safety precautions.

2.4 Inputs and Outputs

Details on the various input and output connections for the DKG-205 unit, including serial data and contactor controls.

2.4.1 Serial Data and Mains;Generator Connections

Details serial data port and essential mains/generator phase and neutral connections for operation.

2.4.2 Auxiliary Relay Output Functions

Explains the four programmable functions of the auxiliary relay output, including alarm and preheat.

2.4.3 Engine Control and Auxiliary Outputs

Details outputs for engine cranking, fuel solenoid, preheat, choke, and other auxiliary functions.

2.4.4 Power Supply and Input Alarms

Covers DC power connections, program lock input, and various alarm/switch inputs.

2.4.5 Safety and Monitoring Inputs

Details emergency stop, overload, and high temperature/oil switch inputs for safety and monitoring.

2.5 Digital Display

Explains the information displayed on the unit's digital screen and how to view different parameters.

2.6 LED Indicators

Description of the function and color of each LED indicator on the control panel.

2.7 Periodic Maintenance Display

Details the periodic maintenance feature, programmable intervals, and how the request display functions.

2.8 Alarms Overview

Explains how alarms indicate abnormal situations, their effect on the engine, and alarm relay activation.

2.8.1 Specific Alarm Conditions

Details specific alarms like Alternator High Temp, Oil Alarm, Voltage Alarm, Fail to Start, and Spare Alarms.

2.9 Modes of Operation

Describes the different operational modes: OFF, MANUAL, START, STOP, AUTO, and TEST, and their functions.

3. MAINTENANCE

4. TROUBLESHOOTING

4.1 Troubleshooting Specific Scenarios

Addresses issues such as no start with OIL PRESSURE ALARM, FAIL TO START alarm, late engine cranking, and unit inoperability.

5. PROGRAMMING

5.1 Programming Parameters Explained

Details programming parameters P14-P20, including timers, relay configurations, and maintenance periods.

6. CALIBRATION

7. TECHNICAL SPECIFICATIONS

8. DECLARATION OF CONFORMITY

9. CONNECTION DIAGRAM

Summary

2. INSTALLATION

2.1 Introduction to the Control Panel

The control panel offers user friendliness and programmable parameters for complete control of the generating set.

2.2 Mounting the Unit

The unit is designed for panel mounting and fits into a standard panel meter opening of 140x68 mm.

2.3 Wiring the Unit

Instructions and warnings for wiring the unit, including fuse requirements and safety precautions.

2.4 Inputs and Outputs

Details on the various input and output connections for the DKG-205 unit, including serial data and contactor controls.

2.4.1 Serial Data and Mains;Generator Connections

Details serial data port and essential mains/generator phase and neutral connections for operation.

2.4.2 Auxiliary Relay Output Functions

Explains the four programmable functions of the auxiliary relay output, including alarm and preheat.

2.4.3 Engine Control and Auxiliary Outputs

Details outputs for engine cranking, fuel solenoid, preheat, choke, and other auxiliary functions.

2.4.4 Power Supply and Input Alarms

Covers DC power connections, program lock input, and various alarm/switch inputs.

2.4.5 Safety and Monitoring Inputs

Details emergency stop, overload, and high temperature/oil switch inputs for safety and monitoring.

2.5 Digital Display

Explains the information displayed on the unit's digital screen and how to view different parameters.

2.6 LED Indicators

Description of the function and color of each LED indicator on the control panel.

2.7 Periodic Maintenance Display

Details the periodic maintenance feature, programmable intervals, and how the request display functions.

2.8 Alarms Overview

Explains how alarms indicate abnormal situations, their effect on the engine, and alarm relay activation.

2.8.1 Specific Alarm Conditions

Details specific alarms like Alternator High Temp, Oil Alarm, Voltage Alarm, Fail to Start, and Spare Alarms.

2.9 Modes of Operation

Describes the different operational modes: OFF, MANUAL, START, STOP, AUTO, and TEST, and their functions.

3. MAINTENANCE

4. TROUBLESHOOTING

4.1 Troubleshooting Specific Scenarios

Addresses issues such as no start with OIL PRESSURE ALARM, FAIL TO START alarm, late engine cranking, and unit inoperability.

5. PROGRAMMING

5.1 Programming Parameters Explained

Details programming parameters P14-P20, including timers, relay configurations, and maintenance periods.

6. CALIBRATION

7. TECHNICAL SPECIFICATIONS

8. DECLARATION OF CONFORMITY

9. CONNECTION DIAGRAM

Datakom DKG-205 Specifications

General IconGeneral
BrandDatakom
ModelDKG-205
CategoryController
LanguageEnglish