EasyManuals Logo

Datalogic DS2 Ethernet User Manual

Datalogic DS2 Ethernet
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
DS2 Ethernet Instruction Manual
34
b. Scanning suspension command - 0x44 (‘D’ ASCII)
Momentary suspends the scanning and passes the control to the host.
Host sends:
0x02
0x01
0x44
0x03
0xBA
DS2 responds:
0x02
0x01
0x64
0x03
0x9A
The following figure is similar to the previous one with the difference that the scanning now does not
re-start automatically after receiving the command (see point 9).
c. Scanning re-start command - 0x45 ( ‘E’ ASCII)
Informs DS2 to re-start the normal scanning mode and the host looses the line control.
Host sends:
0x02
0x01
0x45
0x03
0xB9
DS2 replies:
0x02
0x01
0x65
0x03
0x99
In this case the SYN codes do not have to be sent as the scanning is suspended.
The command is accepted immediately. After the exchange of the packets (see points 1 and 2),
DS2 re-starts the scanning (see point 3).
answer 0x64
command 0x44
answer 0x65
command 0x45