LED and Beeper Indications
Quick Reference Guide 33
Reader
Disabled
The reader has
been disabled
by the host.
The LED
blinks contin-
uously
N/A
Green Spot is
on continu-
ously
While in Stand
Mode or Trig-
ger Stand Mode
the green spot
shall be on
while in stand
watch state.
N/A N/A
Green Spot
a
flashes
momentarily
Upon success-
ful read of a
label, the soft-
ware shall turn
the green spot
on for the time
specified by the
configured
value.
N/A N/A
Programming Mode
- The following indications ONLY occur when
the reader is in Programming Mode.
Label Pro-
gramming
Mode Entry
A valid pro-
gramming label
has been
scanned.
LED blinks
continuously
Reader sounds
four low fre-
quency beeps.
Label Pro-
gramming
Mode Rejec-
tion of Label
A label has
been rejected.
N/A
Reader sounds
three times at
lowest fre-
quency and
current vol-
ume.
Label Pro-
gramming
Mode Accep-
tance of Par-
tial Label
In cases where
multiple labels
must be
scanned to pro-
gram one fea-
ture, this
indication
acknowledges
each portion as
it is success-
fully scanned.
N/A
Reader sounds
one short beep
at highest fre-
quency and
current vol-
ume.
INDICATION DESCRIPTION LED BEEPER