Standard Command
Index (dec) Command Name Lenght Value (dec) Description Access*
0x0002 (2) SP1 Teach TP1 1 octet 0x43 (67) Acquisition FINE: Mark Detection (refer to User’s Manual) WO
0x0002 (2) SP1 Teach TP2 1 octet 0x44 (68) Acquisition FINE: Background Detection (refer to User’s Manual) WO
0x0002 (2) Teach Dynamic 1 octet 0x4B (75) Dynamic acquisition WO
0x0002 (2) Teach Dynamic End 1 octet 0x4F (79) Exit from Dynamic Detection WO
0x0002 (2) Restore Factory Settings 1 octet 0x82 (130)
Restore factory settings: Device Access Locks, Application Specic Tag, Function Tag, Location Tag, SSC1 Param, SSC2 Param, Delay Settings, Output Type,
RGB Selection, Device Temperature Thresholds, Emission Color, Sensitivity
WO
0x0002 (2) Conrm Maintenance 1 octet 0xA5 (165)
Reset Maintenance parameters (Operating Hours Maintenance, Minimum device temperature since powerup, Maximum device temperature since powerup,
Device Status, Detailed Device Status)
WO
0x0002 (2) Disable/enable emission 1 octet 0xB0 (176) Toggle emission (enable / disable emission) WO
0x0002 (2) Start / Stop Ping 1 octet 0xAF (175) Feature to identify the sensor by yellow LED blinking WO
Events
Event code (dec) Event name Event mode Event type Device status Remarks
0x4220 (16928) Temperature underrun Appears / Disappears Warning Out of specication
0x4210 (16912) Temperature overrun Appears / Disappears Warning Out of specication
0x5100 (20736) General power supply fault Appears / Disappears Error Failure
0x7710 (30480) Short circuit - Check installation Appears / Disappears Error Failure
PROCESS DATA
DEVICE VARIANT COLLECTION
Product name Product ID Product text
S100-PR-5-W00-OZ 10004 Contrast sensor
(2)
Process data will not be valid in case of out-of-range values.
821006951 Rev.B
Bit oset
Process Data Input
Byte 0
7 6 5 4 3 2 1 0
Not used TEACH-IN SSC2 (DO pin) SSC1 (C/Q pin)