EasyManua.ls Logo

Datalogic IO-Link S100 Series - Physical Layer; Service Data

Datalogic IO-Link S100 Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S100
parameters
PHYSICAL LAYER
Description
IO-Link Revision 1.1
SIO Modus YES
Min Cycle Time 2.3 ms
Transmission Rate 38.4 kbit/s (COM2)
Process Data Length
PDInput: 3 Bit (M10, T10), 4 Bit (B10)
PDOutput: Not used
M-Sequence Capability
PREOPERATE: TYPE_0
OPERATE: TYPE_2_1
ISDU: supported
FEATURES
Description
Block Parameter YES
Data Storage YES
Supported Access Locks
Parameter (write) access
Data Storage
Prole Characteristic
Device Prole: Smart Sensor
Function Class: Device Identication
Function Class: Switching Signal Channel
Function Class: Device Diagnosis
Function Class: Teach Channel
Function Class: Teach-in Single Value
SERVICE DATA
The following ISDUs will not be saved via Data Storage: Device Access Locks (index 0xC), Teach-in Channel (index 0x3A)
System Parameters
Index (dec)
Parameter
Object Name
Lenght
Subindex
(o󰀨set)
Value/Range Description Data Type Access*
0x000C (12)
Device Access
Locks
2 octets Bit 1: Data Storage (0 = unlocked, 1 = locked)
Standardized Device locking functions:
Bit 0: Parameter (write) access (Not used)
Bit 1: Data Storage
Bit 2: Local parameterization (Not used)
Bit 3: Local user interface (Not used)
Bit 4-15: Reserved
RecordT R/W
0x000D (13)
Prole
Characteristics
2 octets
2 octets
2 octets
2 octets
2 octets
2 octets
0x0001
0x8000
0x8001
0x8003
0x8004
0x8007
Smart Sensor Prole
Device Identication
Switching Signal Channel (SSC)
Device Diagnosis
Teach Channel
Teach-in single value
ArrayT of
UIntegerT16
RO
0x000E (14)
PDInput
Descriptor
3 octets
3 octets
3 octets
3 octets
0x01.0x01.0x00
0x01.0x01.0x01
0x01.0x01.0x02
0x01.0x01.0x03
SSC1 (OUT0)
SSC2 (OUT1)
TEACH STATUS FLAG
ALARM (B10 only)
ArrayT of
OctetStringT3
RO
*RO = read only, WO = write only, R/W = read/write