Cleaning Procedure
QUICK REFERENCE GUIDE   
23
CLEANING PROCEDURE
Exterior  surfaces  and  scan  windows  exposed  to  spills,
smudges  or  debris  require  periodic  cleaning  to  ensure
best performance during scanning.
Common Cleaning Solutions
The  cleaners  and  disinfectants  listed  below  are  recom-
mended  for  use  on  Datalogic  Disinfectant-Ready  Enclo-
sures.
CAUTION:  Do  not  use  abrasive  pads  or  cleaning
agents.
CAUTION:  Be  sure  to  turn  off  power  and  unplug
the device from electrical outlet before cleaning.
PRODUCT CHEMICAL CONTENT
Sani-Cloth® HB,
Sani-Cloth® Plus,
Super Sani-Cloth®
Quaternary Ammonium Chloride 
solution 
Hepacide Quat II Virucidal disinfectant cleaner
Alcohol Wipes 70% Isopropyl Alcohol
CaviWipes™
lsopropanol 10-20%; Ethylene Glycol 
Monobutyl Ether 1-5% 
Virex® 256
n-Alkyl Dimethyl Benzyl Ammonium 
Chloride; Didecyl Dimethyl 
Ammonium Chloride
Formula 409® Glass and 
Surface Cleaner
n-Alkyl Dimethyl Benzyl Ammonium 
Chloride; n-Propoxypropanol
Windex® Blue lsopropyl Alcohol
Clorox® Bleach;
Clorox Healthcare Bleach 
Germicidal Cleaner 
Sodium Hypochlorite;
Sodium Hydroxide
Hydrogen Peroxide 3%
ProSpray™ Wipes 
(Disinfectant towelettes}
0.647% o-phenylphenol;
0.070% o-benzyl-p-chlorophenol
100% Gentle dish soap 
and water