Technical Specifications
12 PowerScan™ PM9501-AR
Technical Specifications
The following tables contain Physical and Performance
Characteristics, User Environment and Regulatory infor-
mation.
Physical Characteristics
Dimensions
Height: 212 mm
Length: 110 mm
Width: 74 mm
Weight
PM9501-ARXX: 460 g
PM9501-DARXX: 485 g
PM9501-DKARXX: 485 g
Electrical Characteristics
Battery Type Li-Ion battery pack
Charge time for
full charge from
full discharge
4,5 hours with external power supply adapter
a
a. Charge Times are much lower when battery is within daily typical operating
condition.
Typical 10 hours with Host power (in this case
no supply adapter is needed)
a
Operating auton-
omy (continuous
reading)
40,000 + reads (typical, @25°C)
Cradle consump-
tion and DC input
supply range
Volt 10-30 VDC; Power < 8 W
b
;
Max 500 mA when in host/bus powered
mode
b
.
b. Typical input current measured under factory default configuration.
Performance Characteristics
Light Source LED
Roll (Tilt) Tolerance ± 180°
Pitch Tolerance ± 80°
Skew (Yaw) Toler-
ance
± 60°
Field of View 14° x 10.5° up to 1m. Over 3 m: 14.4° x 10.8°
Print Contrast Mini-
mum
15% minimum reflectance
Resolution
Max resolution 1D 3mils
Max resolution 2D 4 mils