Technical Specifications
14 PowerScan™ PM9501-AR
User Environment
Operating Tempera-
ture
-4° to 122° F (-20° to 50° C)
Storage Temperature -40° to 158° F (-40° to 70° C)
Humidity 0 to 95% non-condensing
Drop Specifications
Scanner withstands up to 50 times 6.5'
(2 m) drops to concrete
Ambient Light Immu-
nity
100,000 Lux
Contaminants: Spray/
rain,
Dust/particulates
IP65
ESD Level 20 KV
Beeper/Speaker >= 80 dB @ 10 cm
Regulatory
See the Regulatory Addendum for details.
Radio Features
Frequency work-
ing center
433.920 MHz 910 MHz
Programmable
Speed
19.2 kb/s
115.2 kb/s
500 kb/s (default)
36.8 kb/s
500 kb/s (default)
Typical Range
(in open air)
50 m (at 500kb/s)
120 m(at 19.2kb/s)
140 m (at 500kb/s)
240 m (at 36.8kB/s,
frequency hopping)
50 m (at 36.8kb/s,
fixed channel)
Max number of
devices per base
station
16