Batch Mode
This option specifies whether to store labels in the handheld while disconnected from
the base. Options are as follows:
Disabled — The handheld will not store/batch labels.
Automatic — The handheld will store labels to RAM when the handheld goes out
of range and is disconnected from the remote device.
Manual — The handheld will always store labels to Flash memory. The user must
manually send the stored labels to the remote device using a special "batch send"
label.
Send Batch
When the reader is configured in Manual Batch Mode, use the following bar code to ini-
tiate sending of labels stored in batch memory.
Send Batch
BatchSend
$CBTBM00
Batch Mode = Disable
Batch Mode = Automatic
$CBTBM01
$CBTBM02
Batch Mode = Manual
NOTE: Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunc-
tion with this bar code.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM96 Series and is the answer not in the manual?

Datalogic PowerScan PM96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PM96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals