Chapter 3 - Printer Operation  26 
Advanced Entry Calibration (continued) 
 
Step  Action  Displayed Message  Comment 
F 
Use the UP and DOWN Arrow 
buttons to set the Gain Number to 
00. 
 
Record the sensor reading as a 
Label Value for Gain Number 00 in 
a table (32 rows by four columns, 
with headings similar to those 
shown below.) 
TRAN SENSOR GAIN 
00 
(0 - 31) 
This is the Label Value for a gain 
setting of 00. 
 
 
Sample Calibration Table 
Gain Number  Label Value  TOF Value  Difference Value 
00 252     
01      
02      
…      
31      
 
 
 
Step  Action  Displayed Message  Comment 
G 
Use the UP and DOWN Arrow 
buttons to increment the Gain 
Number by one and then Record 
the Label Value.  
 
Repeat this process for each Gain 
Number. 
TRAN SENSOR GAIN 
01 
(0 - 31) 
 
This is the Label Value for a gain 
setting of 01. 
 
 
Sample Calibration Table 
Gain Number  Label Value  TOF Value  Difference Value 
00 252     
01 250     
02 248     
… …     
31 09