Chapter 3 - Printer Operation  28 
Advanced Entry Calibration (continued) 
 
Step  Action  Displayed Message  Comment 
J 
Use the buttons to increment the 
Gain Number by one. Record the 
TOF Value. Repeat this process for 
each Gain Number.  
TRAN SENSOR GAIN 
 
yyy                    (0 - 31) 
                                01 
These are TOF Values, where 
“yyy” represents the current 
sensor reading. 
 
Sample Calibration Table 
Gain Number  Label Value  TOF Value  Difference Value 
00 252 248   
01 250 245   
02 248 234   
… … …   
31 09 14   
 
 
Step  Action  Displayed Message  Comment 
K 
In your sample calibration table, 
where both the Label Value and 
TOF Value are at least 20, subtract 
the amounts and record the result 
as a Difference Value (see below). 
 
Identify the largest Difference 
Value and the corresponding Gain 
Number. This Gain Number will be 
used to resample the media. 
TRAN SENSOR GAIN 
 
yyy                    (0 - 31) 
                                31 
In this example, Gain Number 18 
is chosen because, where both 
values are at least twenty, it has 
the highest Difference Value. 
 
Sample Calibration Table 
Gain Number  Label Value  TOF Value  Difference Value 
00 252 248  4 
01 250 245  5 
02 248 234 14 
… … … … 
15 188 63 125 
16 184 51 133 
17 179 38 141 
18  174  25  149 
19 170 19 N/A 
… … … … 
31 132 14 N/A