DISPLAYED ITEM  ITEM DESCRIPTION 
FAULT HANDLING  Determines the intervention required and the disposition of the label in process 
when a fault occurs, where: 
LEVEL  Selects the user action and the reprint status upon declaration of a fault, where: 
NO REPRINT  Printing stops and a fault message is displayed. Following correction of the 
problem, the FEED Key must be pressed to clear the fault, but the label in process 
is not reprinted. 
STANDARD  Printing stops and a fault message is displayed. Following correction of the 
problem, the FEED Key must be pressed to clear the fault then the label in process 
is reprinted. (Default Setting.) 
VOID AND 
RETRY 
Depending upon the RETRY COUNT (see below), one of the following occurs:  
 
If the count has not been exceeded, VOID is printed (see VOID DISTANCE) on the 
failed label and reprinting automatically occurs;  
 
If the count has been exceeded, printing stops and a fault message is displayed. 
Following correction of the problem, the FEED Key must be pressed to clear the 
fault before the label in process is reprinted; or,  
 
If the CANCEL Key is pressed, reprinting is optional: to reprint press NO; or, to 
cancel the reprint press YES (and press YES again to cancel the batch.) 
 
 
(1) With no Linear Scanner attached, the printer will perform in 
the STANDARD setting, except that VOID will be printed on the 
faulted label.   
 
(2) VOID will not be printed if insufficient text space exists (see 
VOID DISTANCE, below), or if the fault occurred after printing. 
 
(3) The text can be customized, see the Programmer’s Manual 
for details. 
 
VOID DISTANCE  Sets the distance to backup and then print VOID on a faulted label, where:    
(0.09 – 2.00 
in.) 
0.50 
Is the distance, measured from the trailing edge of the label, which indirectly 
establishes the font size of the text. (The default setting is 0.5 inches.)  
RETRY COUNT  Sets the number of reprint attempts, where:  
(0 – 3) 
1 
Is the last label in the count to be voided before the printer will stop and display a 
fault message.  (The default setting is one.)  
 
 
Retry counts greater than 1 are only valid for printers equipped 
with the Linear Scanner or RFID option. 
 
BACKFEED ON 
CLEAR  
Determines the printer's action after a fault is cleared, where:    
ENABLED    Backup label positioning will occur after the fault is cleared. 
DISABLED    No backup label positioning will occur after fault clearing; the printer will assume 
that the current position is correct. (This is the default setting.) 
 
If reloading media, the label must be placed its presented 
position. 
 
SCL FONT BOLD 
FACTOR 
Sets a scalable font boldfacing amount, where:  
08   (1 – 36)  Is the setting, based on an incrementing scale, where eight (08) is nominal.